Pollutants Standard modules

2 of the following modules

NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,
optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,
optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,
optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data
Dimensions (H/W/D, w/o handle and sample inlets) 890/782/400 mm
35/30.8/15.8 in.
Weight 65.8 kg/145.1 lbs
Power consumption* max. 670 W
Flow <2000ccm/min +2000 ccm/min for nephelometer
  • Construction:
    Well-isolated double aluminium construction
    Standard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting brackets
    Wireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Pollutants Standard modules

4 of the following modules

NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,
optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,
optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,
optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data
Dimensions (H/W/D, w/o handle and sample inlets) 1120/782/400 mm
44.1/30.8/15.8 in
Weight 73.9 kg/162.9 lbs
Power consumption* max. 670 W
Flow <3000ccm/min +2000ccm/min for nephelometer
  • Construction:
    Well-isolated double aluminium construction
    Standard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting brackets
    Wireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Pollutants Standard modules

2 of the following modules

NO/NO2/NOX Weight: 12.0 kg/26.5 lbs optional: span module
NH3 Only combined with NOX module
O3 Weight: 5.8 kg/12.8 lbs,
optional: span module
SO2 (H2S) Weight: 8.5 kg/18.7 lbs,
optional: span module; optional: H2S module
CO Weight: 9.0 kg/19.8 lbs,
optional: span module

More sensor modules

  • Photoionisation detector (PID) for volatile organic compounds (VOC)
  • Nephelometer for indicative PM monitoring (PM10, PM2.5)
  • Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
  • Traffic data sensors: traffic count, made by various manufacturers
  • Noise sensors, made by various manufacturers
  • Electrochemical sensors for formaldehyde, ethane, chlorine…
  • For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
  • Sensors for monitoring indoor CO2 (IAQ)
  • Navigation system (GPS) for linking monitoring data with geographical data

Type approved PM10 or PM2.5 monitor (Thermo 5030 SHARP, Met One BAM1020)

Dimensions (H/W/D, w/o handle and sample inlets) 1200/782/615 mm
47.2/30.8/24.2 in.
Weight 110 kg/242.5 lbs
Power consumption* max. 1100 W
Flow  <2000ccm/min +16.7l/min for PM monitor
  • Construction:
    Well-isolated double aluminium construction
    Standard monitoring modules on removable drawers
    Rugged, inconspicuous burglar-proof design
  • Standard equipment:
    Internal air conditioning and temperature control
    Maintenance door
    Cylinder lock (standard)
    Zero air supply
  • Operating temperature
    -20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F)
  • Options
    Various types of mounting brackets
    Wireless communication (GPRS, 3G,…)
    Sample gas conditioning (high relative humidity, high PM exposure)
    Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
    Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
    Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)

Personalize your airpointer

The airpointer is delivered in an unobtrusive design and can therefore blend in with its surroundings. By designing the front of the airpointer as you like you can purposely make it conspicuous or use it as advertising space.

QA/QC

Many years of security, reliability and continuity
The airpointer has been developed by experts with field experience with special emphasis placed on data quality assurance. recordum quality management is certified for research, development and production in accordance to ISO 9001:2008 standards.
Only a minimum amount of maintenance is necessary to continuously guarantee the quality of the measurement data. The filter, absorbent and zero air cartridge should be checked regularly while the device is operating. The modules and electronics must be checked once a year. The airpointer is equipped with a large number of functions for controlling and maintaining operation, which are easy to use, clearly displayed, and quickly implemented.

Calibration
A span gas port in the maintenance door is provided for calibrating the airpointer with external span gas. The user does not have to open the front door thus leaving the temperature inside unaltered. The airpointer is calibrated using a graphic interface in the user menu, which displays the parameters to be calibrated in a concentration-time-diagram. Thus the user may evaluate stability of both measurement signal and span gas concentration. After calibration, the airpointer displays a message indicating whether or not the calibration was successful. The calibration data are saved and can be retrieved at any time.

Software
A user network connection (RJ45) located behind the maintenance door is provided for local operation and monitoring of all device functions. Extensive diagnostic functions included in the software are used to continuously monitor all key operating parameters and save them once a minute in the system data base for preventive fault detection and tracking the effect of faults on measurement data.
A separate program (watchdog) additionally controls correct operation and automatically repairs any faults that may occur. Changes of site, calibrations, faults and their remedies etc. can be entered in an electronic station logbook. You may further increase data security by using an automatic backup with the recordum portal independent of the airpointer.

Operational test

Each airpointer features internal zero air generation for automatic or manual zero point check of each module. You may individually select a zero point check or an automatic adjustment.

You may optionally check all gas ambient air analyzer modules individually using internal span gas generation and the following methods.

Ozone:
An ozone generator generates a constant sample flow of ozone using a UV lamp.
Carbon Monoxide:
Span is generated using a refillable calibration gas
cylinder and an internal dilution system.
Nitrogen Dioxide, Sulfur Dioxide/Hydrogen Sulfide:
A permeation tube contains the condensed airborne pollutant in liquid form and releases it at a constant high temperature (ensured by a controlled oven) via a membrane.

The user may track at all times the results of the internal operational test that are saved in the airpointer database.

 

Filter changing
The filter holder is also located in the vicinity of the maintenance door. The filter holder features a glass plate to check the cleanliness of the filter and if it is properly seated. An optional extended lifetime filter with a greater volume extends the intervals between filter changes.