Manage your dust removal process
Official Emissions Measuring – QAL1
•Automatic range setup
•No manual adjustment required
•Automatic drift compensation
•No optical windows to be cleaned

S301
Equipped with two independent alarm relays that can be used for early warning and failure, or connected to alarm-devices, S301 is used to detect filter deterioration and blockage or breakage. The alarms can be used for process control (as an ON-OFF system)
in flow – no flow situations in bulk solids handling and pneumatic transport applications. Very fast response time, a typical characteristic of these monitors, enables early detection and prevention of expensive product loss to the environment.
S303
With a 4–20 mA analog signal output used for trend monitoring, S303 is installed downstream from a filter, cyclone, dryer or similar devices to monitor filter performance as well as particulate emissions. It has two alarm relays that will engage when particulate levels
in the gas stream exceed a preset level. It can also be used for process control in certain applications. S301 and S303 are designed for use in any process fitted with bag, ceramic, cartridge filters or cyclones where indicative (qualitative) monitoring is required.

S304
Combining the S303’s features with the added feature of allowing calibration to give readings in mg/m3 format, it can give plant operators the ability to see absolute value measurements of dust concentrations. Installed in emissions stacks or in common ducts of a stack, the S304 can give a continuous dust concentration in the process enabling constant monitoring of the dust levels.
S305
Equipped with a Self Zero and Self Span check, the S305 meets all QAL1 requirements for official emissions regulations, as proven by its TÜV certification. Used for emissions monitoring in official stack measurements for reporting to authorities as well as providing a mg/m3 reading to plant operators. Gives plants a continuous measurement of particulate emissions to ensure it remains within its imposed regulatory limits.
ATEX Models
●Certified for ATEX Zone 20, 21 or 22
●Approved to Category II 1/2 for Gas and Dust
●IP65 Enclosure, Custom Designed
●Certification Type: II 1/2 GD EEx ia IIC, T6, IP65, 85°C
●Utilizing SINTROL’s Advanced Inductive Electrification Technology
The ATEX directive covers health and safety of workers potentially at risk from exposure to explosive environments. This directive classifies areas into Zone 0, 1, 2 for gas and 20, 21 or 22 for dust and guides plant operators to install the appropriate ATEX certified systems. Products are required to be categorized by the level of protection that they offer against the risk of them becoming a potential source of ignition in an explosive atmosphere. The equipment conformity categories are 1, 2 & 3.

Special Features

S301S303S304S305
2 Independent alarm relays
(user selectable alarm limits, NO or NC)
4–20 mA signal output
Remote setup & configuration
Self zero check
Span check
Filter bag leak detection
Filter performance
Particulate emissions monitoring in mg/m3
Certified emissions monitoring in mg/m3
Serial communication
ATEX approved modelxxxx
Remote modelsxxxx

✓ Standard x Optional

Split Architecture (Remote) Models
S300 Series includes the following remote models: S311, S313, S314 and S315. The remote models are used when the sensor has to be installed with the control unit up to 200 meters away. In these models, the sensor is connected to an enclosure housing the preamplifier (PA) and the amplified signal is transmitted with a 4-wire shielded cable using one of the recommended cables.

Industrial Applications
●Cement
●Chemical processing
●Metallurgical
●Foundries
●Pharmaceutical
●Fertilizers
●Wood processing
●Food
●Tobacco
●Animal feed processing
●Power plants
●Waste incinerators
●Pulp and paper

Measurement Objects:
Solid particles in a gas flow
Particle Size:
0.3 μm or larger
Measurement Range:
From 0.1 mg/m3
Measurement Principle:
Inductive Electrification
Protection Category:
IP65

Probe Length (total/measuring):
500 mm / 440 mm, 750 mm / 690 mm (optional), 1000 mm / 940 mm (optional),
> 1000 mm on request
19.7″ / 17.3″, 29.5″ / 27.2″, 39.4″ / 37.0″ (optional), > 39.4″ on request

Power Supply:
115 VAC, 230 VAC or 24 VDC

Power Consumption:
DC model Max 3 W, AC model Max 8 W

Wiring Connections – Power Supply:
DIN PG11 cable gland

Wiring Connections – Output Signals:
DIN PG11 cable gland

Process Connection:
Socket (38 mm OD), quick clamp (optional), flange (optional)

Output Signals:
–Isolated 4 – 20 mA, (not available in S301)
–Two SPDT relays: 5 A, 24 V AC / DC

Communication Interface:
Serial communication RS-485
Communication Protocol:
Modbus RTU

Range Set Up:
–Normal measuring range: automatic, based on average measured dust flow during setup procedure
–Extended measuring range: User selectable (not available in S305)

Relay Alarm Settings:
–Automatic, set at factory: Based on average measured dust flow
–User selectable ranges

Offset Trim:
Automatic drift compensation
Signal Damping Time (mA):
10 – 300 s

Relay Delay Time:
10 – 180 s

Process Conditions

Temperature:
Max 300 °C, Max 700 °C (optional)
Max 572 °F, Max 1292 °F (optional)

Pressure:
Max 300 kPa, Max 600 kPa (optional)
Max 43.5 PSI, Max 87 PSI (optional)

Gas Velocity:
Min 4 m/s ı Min 13.1 ft/s
Humidity:
Max 95 % RH (non-condensing)
Ambient Conditions
Temperature:
-20 to +45 °C and to 60 °C for 24 VDC
-4 to 113 °F and to 140 °F for 24 VDC
Humidity:
Max 95 % RH (non-condensing)
Vibration:
Max 5 m/s2 ı Max 16.4 ft/s2
Materials and Weight

Probe (wetted part):
Stainless steel (AISI 316L)

Probe Coating (wetted part):
PTFE Teflon (optional)
Process Connection (wetted part):
Stainless steel (AISI 316L)

Probe Insulation (wetted part):
PEEK

Probe Sealing (wetted part):
FPM Viton

Enclosure:
Aluminum alloy

Weight:
2.3 kg ı 5.1 lb